Avery ALS 256 Manual do Utilizador Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 58
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 25
22
CONTENTS
2.3 OPERATING MODES
ALS
20x
256
GB
Online settings
The machine is in dispensing mode.
To switch to the online settings mode:
£ Press the button.
The display shows the dispensing speed [21A] and
the start offset [21C].
The button assignments are as shown on the
buttons.
You can increase (‘+’ button) or lower (‘–’ button)
both settings in the dispensing mode
[21D].
Dispensing speed:
Setting range:
ALS 204: [2.0…40.0] m/min
ALS 206: [2.0…30.0] m/min
Display fix: The dispensing speed is constant.
Display var: The dispensing speed automatically
adjusts to the speed of the conveyor belt (‘speed
adaption’).
Start offset:
Setting range: [0.0…999.9] mm
The start offset indicates the distance between the
product sensor and the dispensing edge.
Dispensing manually
To manually trigger the dispensing of individual
labels:
£ Press the button.
Dispensing speed: As specified in the setting (see
above).
To switch back to dispensing mode:
£ Press the buttons + .
[21] Control panel in the online settings mode
A Dispensing speed display (here: 12.2 m/min constant)
B Dispense label button
C Start offset display (here: 0 mm)
D Explanation of buttons in online settings mode
E Button to lower dispensing speed
F Button to increase dispensing speed
G Button to lower start offset
H Button to increase start offset
+
+
ON
STATUS
Speed
12.2 fix
Offset
0.0
ABC
D
EFGH
Vista de página 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 57 58

Comentários a estes Manuais

Sem comentários