Configuring the Partner Printer
The partner printer must be configured to 115200 Baud, No parity,
8-bit word length, 1 stop bit, and XON/XOFF flow control.
1. Select Setup, Port Settings, Serial Comm from the partner printer’s
Main Menu. If password protection in enabled, press Feed/Cut three
times, then press Enter/Pause before you see the Setup Menu
options.
2. Select Baud Rate and press or to scroll until you see 115200.
Press Enter/Pause.
3. Press or to select Word Length. Scroll until you see 8.
Press Enter/Pause.
4. Press or to select Stop Bits. Scroll until you see 1.
Press Enter/Pause.
5. Press or to select Parity. Scroll until you see None.
Press Enter/Pause.
6. Press or to select Flow Control. Scroll until you see
XON-XOFF. Press Enter/Pause.
Using the Smart Relay Telnet Commands
See the following list of commands to configure the printers.
SET PRN RELay PORt [None/S2]
Sets the Smart Relay Partner Identification (port) number to None (no partner
printer) or S2 (partner printer connected to serial port 2). The default is None.
Using the Smart Relay System 5-5